Coronary

ASAHI Gaia® Series

Good choice for the need of high penetration while maintaining torqueability. Chronic Total Occlusion indicated.

Low tip load to improve deflection and torqueability.

ASAHI Gaia Series Guide Wire image

Technical Advantages

Deflection and Torque Control

To guide the wire through the occlusion to the distal lumen by using deflection and rotational control.
Gaia Tip Flexibility image

Controllability

Within strong resistance area, ASAHI Gaia experiences higher torque response and less whip motion.
Controllability of Asahi Gaia Guide Wire image

Penetrability by micro-cone tip

The ball tip was made smaller to increase its penetration efficacy.
It makes easier to create the entry route to the hard tissue and fibrous cap.
Gaia micro-cone tip image

Tip flexibility

By taking advantage of tip flexibility, ASAHI Gaia easily avoids hard tissue and advances smoothly.
Deflection control: Guiding the wire to the distal true lumen with rotational control by using deflection which occurs when advancing a shaped GW.
Asahi Gaia Tip Flexibility Chart image

1 mm pre-shaped tip

The pre-shape of the tip is incorporated in the production process, significantly increase tip shape retention.
1 mm Asahi Gaia pre-shaped tip image

Product Spec

Product Specifications: Engineered for Optimal Outcomes

ASAHI Gaia® Series Guide Wire Specs image
TIP LOADASAHI Gaia 1.7gf Tip Load
ASAHI Gaia  3.5gf Tip Load
ASAHI Gaia 4.5gf Tip Load
TIP RADIOPACITY15 cm
COATINGHYDROPHILIC* WITH UNCOATED DISTAL TIP
Hydrophilic 40 cm – uncoated distal tip
TIP SHAPE mini pre-shape tip shape

Ordering Information

Flexible Ordering Options and Dedicated Support

To order, please call us toll-free at 855-286-9473, or email us at customersupport@asahi-intecc.com. To see a complete listing of all available ASAHI products, go to our Full Product Listing page.

Viewing on a smaller screen? Swipe left on the table to see all product details.

ProductCatalog No.Tip ShapeLength (CM)Diameter (INCH(MM))Radiopaque Segment (CM)Spring Coil Length (CM)Coating
ASAHI Gaia FirstAHW14R007PPre-Shape1900.010/0.014 (0.26/0.36)1515Hydrophilic* with Uncoated Distal Tip
ASAHI Gaia First, 300 cmAHW14R307PPre-Shape3000.010/0.014 (0.26/0.36)1515Hydrophilic* with Uncoated Distal Tip
ASAHI Gaia SecondAHW14R008PPre-Shape1900.011/0.014 (0.28/0.36)1515Hydrophilic* with Uncoated Distal Tip
ASAHI Gaia Second, 300 cmAHW14R308PPre-Shape3000.011/0.014 (0.28/0.36)1515Hydrophilic* with Uncoated Distal Tip
ASAHI Gaia ThirdAHW14R011PPre-Shape1900.012/0.014 (0.30/0.36)1515Hydrophilic* with Uncoated Distal Tip
ASAHI Gaia Third, 300 cmAHW14R311PPre-Shape3000.012/0.014 (0.30/0.36)1515Hydrophilic* with Uncoated Distal Tip
*Coated with SLIP-COAT® coating

"ASAHI", "SION" and "ACT ONE" are trademarks or registered trademarks of ASAHI INTECC CO., LTD. in Japan and other countries. Coated with SLIP-COAT® coating.
The tip load values of our guide wires are the values assuming the force that the tip of the guide wire pushes the lesion on the basis of company standardized test. There are individual differences in values of actual devices.

Indications for Use

ASAHI PTCA Guide Wires are intended to facilitate the placement of balloon dilation catheters during percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transluminal angioplasty (PTA). The ASAHI PTCA Guide Wires are not to be used in the neurovasculature.